                                  PERFOM A MEASUREMENT
                                    ➢   Turn on the device by pressing on « On/Off/Esc».
                                        The device displays its name « AQ110 ».
                                        When it turns on, the device performs a pre-heating phase. This phase lasts 10 seconds. The count of this pre-heating time
                                        displays on screen.
                                        The measure probe must be left to the open-air during this pre-heating phase.
                                    ➢   Put the probe to the required location.
                                        The device displays the CO2 and temperature measurements.
                                  FREEZE THE MEASUREMENT
                                    During the measurement :
                                    ➢   Press on « Hold/min/max » to freeze the measurement.
                                        « Hold » appears on the screen and the measurements are frozen.
                                    ➢   Press on « On/Off/Esc » to exit the hold function.
                                        The device returns to the measurements display.
                                  DISPLAY THE MINIMUM AND THE MAXIMUM
                                     Once the measurement is frozen :
                                     ➢   Press on « Hol/min/max ».
                                         The device displays the maximum value of CO² measured since the last questioning at the top of the screen and the minimum
                                         value of CO² measured since the last questioning at the bottom of the screen.
                                     ➢
                                         Press again on « Hold/min/max ».
                                         The device displays the maximum value of temperature measured since the last questioning at the top of the screen and the
                                         minimum value of temperature measured since the last questioning at the bottom of the screen.
                                     ➢   Press on « On/Off/Esc » to return to the measurements display.
                                  ADJUST THE DEVICE
                                    ●
                                         The device drop-down menu
                                                      SEL.                                    SEL.                                SEL.                                  SEL.
                                    1x  Select               UNIT         2x   Select              AUTO         3x   Select             BEEP        4x   Select             P_ATM
                                                                                                  OFF                                                                      900
                                                                C°                                   OFF                                   ON                                  hPa
                                     Select the measuring unit in temperature
                                     The device is on and displays the measurements.
                                     ➢
                                         Press on « Select ».
                                         « UNIT » blinks on screen.
                                     ➢
                                         Press on « OK ».
                                         The unit currently used blinks at the bottom of the screen.
                                     ➢
                                         Press on « Select » until the required unit appears : °C or °F.
                                     ➢   Press on « OK » to validate.
                                         « UNIT » blinks on screen.
                                     ➢   Press on « On/Off/Esc » to return to the measurements display.
                                                            SEL.                                                                                             SEL.
                                         1x   Select              UNIT           OK
                                                                                                   UNIT         Select               UNIT         OK                UNIT
                                                                                            SEL.                              SEL.
                                                                     C°                               C°                           C° / F°                              F°
                                                                                                                                                    1416
                                                                                                                                                    PPm           On/Off/
                                                                                                                                                                    Esc
                                                                                                                                                   77.6
                                                                                                                                                       °F
                                     Adjust the auto shut-off
                                     The device is on and displays the measurements.
                                     ➢
                                         Press on « Select » until « AUTO OFF » blinks on screen.
                                     ➢   Press on « OK », the time before device auto shut-off blinks at the bottom of the screen.
                                     ➢
                                         Press on « Select » to select the time before device auto shut-off : 15, 30, 45, 60, 75, 90, 105, 120 minutes or OFF.
                                     ➢   Press on « OK » to validate.
                                         « AUTO OFF» blinks on screen.
                                     ➢   Press on « On/Off/Esc » to return to the measurements display.
                                                           SEL.                                                                                           SEL.
                                                                 AUTO                           AUTO                             AUTO                           AUTO
                                         2x    Select                           OK                            Select                           OK
                                                                OFF                            OFF                              OFF                           OFF
                                                                   OFF                            OFF                       15 / 30mn...                         30mn
                                                                                                                                               1416
                                                                                                                                               PPm            On/Off/
                                                                                                                                              25.6              Esc
                                                                                                                                                  °C
                                     Activate or deactivate the keys beep
                                     The device is on and displays the measurement.
                                     ➢
                                         Press on « Select » until « BEEP » blinks on screen.
                                     ➢   Press on « OK ».
                                         « OFF » or « ON » blinks on screen.
                                     ➢   Press on « Select » to activate the keys beep « ON » or deactivate it « OFF ».
                                     ➢
                                         Press on « OK » to validate.
                                         « BEEP » blinks on screen.
                                     ➢
                                         Press on « On/Off/Esc » to return to the measurements display.
                                                               SEL.                                                                                       SEL.
                                           3x   Select              BEEP           OK              BEEP         Select             BEEP                         BEEP
                                                                                                                                                OK
                                                                                              SEL.                            SEL.
                                                                       ON                             ON                        OFF / ON                         OFF
                                                                                                                                                1416
                                                                                                                                                PPm          On/Off/
                                                                                                                                                              Esc
                                                                                                                                               25.6
                                                                                                                                                   °C
                                     Adjust the atmospheric pressure
                                     To have a precise and representative measurement, the atmospheric pressure of the place where the measurements are performed
                                     must be entered in the device.
                                     The device is on and displays the measurements.
                                     ➢
                                         Press on « Select » until « P_ATM » blinks on screen.
                                     ➢   Press on « OK ».
                                         The first digit of the atmospheric pressure blinks on screen. The atmospheric pressure is between 800 and 1200h Pa.
                                     ➢   Press on « Select » to select the first digit value and press on « OK » to validate.
                                         The following digit blinks on screen.
                                     ➢   Perform the same procedure for the following digits (press on « On/Off/Hold » to return to the previous digit).
                                     ➢
                                         Press on « OK » when the last digit is adjusted.
                                         « P_ATM » blinks on screen.
                                     ➢
                                         Press on « On/Off/Esc » to return to the measurements display.
                                  ACTIVATE THE BACKLIGHT
                                     The device is on and displays the measurements.
                                     ➢   Press on « Backlight » :       to activate the backlight.
                                     ➢
                                         To deactivate it press again on « Backlight ».
                                  CHANGE THE BATTERIES
                                   ➢  Remove the front part at the back of the device.
                                   ➢  Change the old batteries by AAA LR03 1.5V batteries.
                                   ➢ Replace the front part.