Sound Level Meter

FIVE DIFFERENT MEASUREMENT MODES
- Mode 1 : Conventional sound level meter
- Mode 2 : Conventional sound level meter with storage.
- Mode 3 : Conventional and integrating-averaging sound level meter
- Mode 4 : Integrating-averaging sound level meter with storage.
- Mode 5 : Sound level meter “calculator” of two sound sources.

MEASURED VALUES
- Weighted sound level : L                         - Sound exposure level : LE
- Equivalent continuous level : Leq                - Peak pressure level : Lpk

RESULTS & ADDITIONAL INFORMATION
- Maximum and minimum values, peak values
- L01-L10-L50-L90 statistics distribution of measured values.
- Presence and percentage of overload input stages, measurement time.
- Residual autonomy of batteries or battery, measuring capacity remaining.

 

TECHNICAL FEATURES
Metrology
Accuracy.................................................Class 2                                  Logging time for short Leq (DI).....................from 1 s to 60 s
Microphone type....................................Electret ICP – ½'' -                Sampling for Lp..............................................from 1 s to 60 s
                                                         Sensibility : 15 mV/Pa                 Measured values.............................................LXY – LXYmax – LXYmin -
Measuring type.......................................Free-field                                                                                  LXeq,T – LXeq,DI – LXE –
Measurement dynamic..........................Lp/Leq : 100 dB -                                                                                   LXeq,DImax – LXeq,DImin
                                                         Lpk : 50 dB                                  Statistics indices LXN on
A-weighted measurement range...........30-130 dB                               Lp and Leq samples.......................................LX01 – LX10 – LX50 –
                                                                                                                                                 LX90 – LX95 – resolution 1dB.
C-weighted measurement range...........35-130 dB
                                                                                                              Measured values simultaneously -
Z-weighted measurement range...........35-130 dB
                                                                                                              Storage mode..................................................All according LXY or LXeq choice
Peak channel measurement range.......83-133 dB                              Detection and
X frequency weighting ..........................A – C – Z                               percentage of overload..................................Alarm graphics and calculation of FTang – DB200 – 07/10/10 – RCS (24) Périgueux 349 282 095 Non-contractual document –                      We reserve the right to modify the characteristics of our products without prior notice.
Y frequency weighting...........................F (fast) – S (slow)                                                                              percentage during the storage
                                                         I (impulse) – Peak (pk)

SOUND LEVEL METER

Screen..........................................................................graphic display 240 x 160 pixels – LCD monochrome 16 levels –                                       6 digital and analogue display – 3D effect on display
Keypad.........................................................................8 sensitive keys
Internal clock...............................................................permanent, saved by internal battery
Memory module..........................................................integrated Micro SD card type – data transfer by USB cable
Environment................................................................from -10 °C to +50 °C
Humidity.......................................................................from 0 to 90% HR
Dimensions (L x l x e).................................................270 x 70 x 40 mm
Weight (including batteries).......................................280 gr
Fixing...........................................................................Insert at rear for fixing on tripod

OPERATING
5 measurement modes...............................................conventional – conventional with storage – conventional and integrating – integrating with storage – calculator S1 + S2
Storage and measurement capacity..........................L-Leq mode : 24h L-St or Leq-St mode : according sampling or elementary logging time
Memory capacity : 25 periods of 86 500 values – ex : 24 hours / Leq 1s
I/O Interface : ..............................................................Output 0-10V DC : 0-130dB
                                                                              Start/Stop measurement order : TTL level maximal 5V
                                                                              Output for alarm activation : TTL level 3.3 V
Measurement launching.............................................By keyboard or I/O controlled
Power – Autonomy......................................................Batteries : 3 x LR6/AA – minimum autonomy : 15 hours at 20 °C
                                                                              Optional rechargeable Li-Ion battery : minimum autonomy :more than 24 h at 20 °C
                                                                              Electrical power adapter 5V, USB format.
Guarantee....................................................................2 years

SUPPLIED WITH                                                         ACCESSORIES
Windshield                                                                              ● Tripod
● Transport case                                                                       ● Acoustic calibrator class 2
● 3 LR6-AA batteries                                                                 ● Rechargeable Li-Io battery
● Calibration certificate                                                            ● Charger – electrical power adapter USB type
● Transfer cable USB type                                                        ● Jack cables for I/O interface Acoustic
● LDB200 software calibrator



VECTOR TECHNOLOGIES
X


No. 001, Priya Enclave, Beside E-Seva, Road No. 9, Snehapuri Colony, Nacharam, Hyderabad - 500076, Telangana, India
Phone :+917259709563
Fax :91-40-27170188
Mr. M.R. V. Prasad (Chief Consultant)
Mobile :+917259709563
Send Inquiry Send SMS