CO2ST Sensors
CO2ST Sensors

CO2ST Sensors

CO2ST Sensors Specification

  • Resistance
  • < 100 Ohms
  • Output
  • Analog Voltage
  • Theory
  • NDIR (Non Dispersive Infrared)
  • Type
  • CO2ST Sensor
  • Accuracy
  • 50ppm 5% of reading
  • Operating Voltage
  • 5V DC
  • Output Voltage
  • 0.4V to 2.0V
  • Compensated Temperature
  • 5C to 50C
  • Storage Temperature
  • -20C to 60C
  • Operating Temperature
  • 0C to 50C
  • Interface
  • 3-pin/4-pin
  • Response Time
  • < 2 Minutes
  • Warm-Up Time
  • < 1 Minute
  • Weight
  • 6g
  • Humidity Range
  • 0% to 95% RH non-condensing
  • Measurement Range
  • 0 to 2000 ppm (expandable up to 5000 ppm upon request)
  • Current Consumption
  • < 50 mA
  • Lifespan
  • > 10 years
  • Dimensions
  • 33 mm x 20 mm x 9 mm
 
 

About CO2ST Sensors

CO2ST Sensors:

Our domain expertise has enabled us to come up with quality CO2ST Sensors. The products we offer are designed and engineered under the notable guidance of our diligent professionals. Furthermore, our products are timely delivered at clients disposal, with the assistance of wide distribution network.

CO2 sensors allow you to measure carbon dioxide.

Kimo's CO2ST measures CO2.

Salient Features :

  • Range from 0 to 5000 ppm
  • 10-digits LCD display
  • One RCR relay 3A/230 Vac
  • Red LED in front
  • Software or DIP switch configuration
  • Quick and easy mounting with the 1/4 turn system with wall-mount plate

Technical details(active tab)

Measure details

Alarm : Red led in front and internal buzzer

Sensor

Min

Max

CO2

0.00 ppm

5000.00 ppm

Technical details :

Parameters

CO2

Displays

1-line display

IP Protection

IP 20

Standards

2011/65/EU RoHS II

2012/19/EU WEEE

2014/30/EU EMC

2014/35/EU Low Voltage

Power supply

24 Vac/Vdc

Relay

1 RCR relay 3 A / 230 VAC

Ethernet communication

No

Modbus network

No

Instrument Dimensions :

Length

Width

Height

Weight

90.00 mm

41.00 mm

80.00 mm

138.00 g

Operating temperature :

Min

Max

0.00 C

50.00 C

Storage temperature :

Min

Max

-10.00 oC

70.00 oC

Supplied with

  • 1 ABS plate (expect ambiant model)
  • 1 Fiche technique




Advanced CO2 Monitoring

Harnessing NDIR (Non Dispersive Infrared) technology, the CO2ST Sensor ensures precise and reliable carbon dioxide measurements, essential for environmental monitoring and control. Its high accuracy and wide operating range make it well-suited for indoor air quality applications and industrial use alike.


Seamless Integration for Diverse Industries

Designed with a compact footprint and analog voltage output, this sensor integrates smoothly into existing systems. With a current consumption below 50 mA and compatibility with 3-pin and 4-pin interfaces, installation is straightforward for manufacturers, exporters, and service providers seeking scalable environmental solutions.

FAQs of CO2ST Sensors:


Q: How does the CO2ST Sensor measure carbon dioxide levels?

A: The CO2ST Sensor uses NDIR (Non Dispersive Infrared) technology to accurately detect CO2 concentrations. It measures the absorption of infrared light by carbon dioxide molecules, providing stable and reliable readings for a range of applications.

Q: What are the benefits of using the CO2ST Sensor in indoor air quality monitoring?

A: Deploying the CO2ST Sensor improves indoor air quality management by offering rapid and accurate CO2 measurement. Its quick response and warm-up times, combined with a long lifespan, provide consistent performance with minimal maintenance, benefiting both end-users and service providers.

Q: When should a CO2ST Sensor be recalibrated or replaced?

A: Thanks to its robust design and advanced NDIR detection, the sensor maintains accuracy for over 10 years under normal operating conditions. However, periodic calibration checks are recommended in critical environments or if accuracy issues are detected during use.

Q: Where can the CO2ST Sensor be used?

A: This sensor is versatile and suitable for installation in buildings, laboratories, agricultural settings, and industrial environments within the operating temperature range of 0C to 50C and non-condensing humidity up to 95% RH.

Q: What is the installation process for the CO2ST Sensor?

A: The sensor features a compact design and supports 3-pin or 4-pin connections, making integration straightforward. Connect to a 5V DC power supply, ensure correct pin alignment, and wire the analog voltage output (0.4V to 2.0V) to your monitoring system.

Q: Can the CO2ST Sensors measurement range be customized?

A: Yes, the standard measurement range is 0 to 2000 ppm, but it can be expanded up to 5000 ppm upon request. Contact your dealer, supplier, or manufacturer for customization options as needed for your applications.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Sensors Category

CO2ST Sensors Suppliers

CO2ST Sensors Suppliers

Theory : Other, Infrared Absorption

Accuracy : 3% (4005,000 ppm)

Type : Nondispersive Infrared (NDIR)

Output Voltage : 0.42V (typical)

Operating Voltage : 4.5V 5.5V DC

Storage Temperature : 20 to 60C

Air Velocity And Temperature Sensor Dealers

Air Velocity And Temperature Sensor Dealers

Theory : Other, Temperature Sensor

Accuracy : 0.2 m/s, 1C

Type : Air Velocity And Temperature Sensor

Output Voltage : 010V

Operating Voltage : 1224V DC

Storage Temperature : 40C to +125C

HST Sensors

HST Sensors

Theory : Other, Capacitive and Resistive

Accuracy : 1.5 %FS, 0.5 %FS, 0.25 %FS

Type : Pressure Sensor

Output Voltage : 0.5V 4.5V

Operating Voltage : 5V DC

Storage Temperature : 40C to 125C

CO/Temperature Sensor

CO/Temperature Sensor

Theory : Other, Electrochemical and Semiconductor Hybrid

Accuracy : 10% FS (Full Scale)

Type : CO/Temperature Sensor

Output Voltage : 0.4V to 2.0V (CO), 0.5V to 4.5V (Temperature)

Operating Voltage : 5V DC

Storage Temperature : 20C to 60C



Back to top