VA 570 - Flow meter with integrated measuring section
VA 570 - Flow meter with integrated measuring section

VA 570 - Flow meter with integrated measuring section

VA 570 - Flow meter with integrated measuring section Specification

  • Power Supply
  • 24 V DC (1830 V DC)
  • Measuring Range
  • 0.5 to 700 Nm/h (depending on pipe size)
  • Port Size
  • G1/2 (others on request)
  • Automation Grade
  • Automatic
  • Application
  • Measurement and monitoring of compressed air and non-corrosive gases
  • Interface Type
  • 4-20 mA, pulse, RS485/Modbus
  • Max Height
  • Depending on pipe connection size
  • Gas Pressure
  • Max. 16 bar (232 psi)
  • Response Time
  • 1 second
  • Resolution
  • 0.01 Nm/h (depending on configuration)
  • Mounting Type
  • In-line mounting with integrated measuring section
  • Display Type
  • 2-line LCD display with touch keys
  • Humidity
  • 0 - 95% RH (non-condensing)
  • Operating Voltage
  • 24 V DC (1830 V DC)
  • Features
  • Integrated measuring section, rugged industrial design, easy installation, no moving parts, low pressure loss, maintenance-free
  • Accuracy
  • 1.5% of measured value 0.3% of full scale
  • Equipment Type
  • Thermal mass flow meter / Flow sensor
  • Temperature
  • Medium: -20C to +60C; Ambient: 0C to +50C
  • Usage
  • Industrial, process control, energy management
  • Machine Weight
  • Approx. 1.7 kg (depending on version)
  • Control Mode
  • Microprocessor controlled
  • Measuring Principle
  • Thermal mass flow measurement
  • Max Flow Velocity
  • 224 Nm/s (application dependent)
  • Data Logger
  • Optional (via interface)
  • Display Orientation
  • Configurable
  • Output Signal
  • 4...20 mA, pulse, RS485 Modbus RTU
  • Min Flow Velocity
  • 0.5 Nm/s
  • Approval/Certification
  • CE, EAC (on request)
  • Medium Compatibility
  • Compressed air and non-corrosive gases (e.g. nitrogen, CO, argon, oxygen, etc.)
  • Protection Class
  • IP65
  • Pipe materials
  • Steel, stainless steel, aluminium, copper, plastic
  • Calibration
  • Factory calibrated with traceable certificate
  • Installation Length
  • Standard measuring section integrated, minimal straight pipe requirement
  • Process Connection
  • Threaded or flanged, as per order
  • Power Consumption
  • <1.5 W
 
 

About VA 570 - Flow meter with integrated measuring section



Discover the exclusive VA 570 a sizzling addition to your industrial toolkit, engineered for inestimable accuracy and kingly reliability. This terrific thermal mass flow meter integrates measuring and display sections for effortless compressed air and non-corrosive gas monitoring. Add to cart to experience its configurable orientation, microprocessor-controlled operation, and outstanding signal output versatility. Boasting IP65 protection, rugged design, and factory calibration with traceable certificate, the VA 570 promises minimal installation fuss and maintenance-free operation. Elevate your control with this state-of-the-art flow measurement powerhouse the VA 570.

Versatile Utility and Key Advantages

The VA 570 Flow Meter is expertly used for precise measurement and monitoring of compressed air and non-corrosive gases like nitrogen, oxygen, argon, and CO. Ideal for industrial, process control, and energy management applications, this device offers a major advantage with its in-line mounting and integrated measuring section that minimizes installation requirements. Its broad compatibility with various pipe materials makes it suitable for diverse workplaces, power plants, manufacturing units, and automation sectors.


Efficient Supply, Secure Packaging, Reliable Delivery

Our VA 570 Flow Meter is available for dealers, exporters, manufacturers, and traders across India, with robust supply capability to meet sizable orders. Samples can be provided on proposal amount approval. Carefully packaged to ensure safe transit, the meter is securely handed over for shipment. Delivery timeframes are prompt and tailored to order volume and customization. Experience hassle-free procurement and on-time delivery with every purchase of the VA 570.


FAQs of VA 570 - Flow meter with integrated measuring section:


Q: What gases are compatible with the VA 570 Flow Meter?

A: The VA 570 is designed for compressed air and a range of non-corrosive gases, including nitrogen, carbon dioxide (CO), argon, and oxygen, ensuring versatility for different industrial applications.

Q: How is the VA 570 Flow Meter installed and configured?

A: Installation is straightforward due to the standard measuring section integrated into the unit, requiring minimal straight pipe length. Orientation and display settings can be configured easily to suit various pipe materials and process setups.

Q: What output signals does the VA 570 provide for process integration?

A: It offers multiple signal options, including 4-20 mA, pulse, and RS485 Modbus RTU, making it adaptable for integration with most existing process control and energy management systems.

Q: When should a data logger be selected as an option?

A: A data logger is recommended when ongoing recording and trend monitoring of gas flow data are crucial for analysis, reporting, and system optimization.

Q: What makes the VA 570 advantageous over conventional flow meters?

A: Its thermal mass flow measurement principle delivers 1.5% accuracy, it has no moving parts (supporting maintenance-free operation), and its rugged IP65 housing supports reliable, long-term use in challenging environments.

Q: Where can the VA 570 be applied?

A: You can deploy the VA 570 in varied environmentsindustrial facilities, process automation installations, energy management systems, and any location where dependable gas flow monitoring is essential.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Flow Meter Category

Chart Recorder

Chart Recorder

Mounting Type : Panel Mounted

Application : Industrial Data Logging

Power Supply : 230 V AC, 50 Hz

Usage : Recording process parameters

Features : Longterm Data Recording

Control Mode : Manual/Automatic

VA 525 - Compact in-line flow sensor

VA 525 - Compact in-line flow sensor

Mounting Type : Inline, directly into pipe system

Application : For compressed air and noncorrosive gases

Power Supply : 24 V DC 10%

Usage : Flow measurement in compressed air systems

Features : Bidirectional measurement, compact design, easy installation, maintenancefree

Control Mode : Digital, Automatic

Digital Process Meter

Digital Process Meter

Mounting Type : Panel Mount

Application : Measuring and indicating process signals

Power Supply : 230V AC, 50/60Hz

Usage : Industrial process measurement

Features : High brightness LED, Multirange input, Overrange indication, Compact design

Control Mode : Manual/Automatic

VA 500 - Flow sensor for compressed air and gases

VA 500 - Flow sensor for compressed air and gases

Mounting Type : Insertion type

Application : Measurement of compressed air and technical gases

Power Supply : 1836 V DC

Usage : Inline or insertion flow measurement in pipes/ducts

Features : Bidirectional measurement, easy installation, IP65 protected, menu operation via touch buttons

Control Mode : Digital/Analog Output control



Back to top